CHVKJ - SYNCHRON EL-ISE ACID REAGENT, 441082
- MSDS: CHVKJ
- Manufacturer: BECKMAN INSTRUMENTS INC
- Product Name: SYNCHRON EL-ISE ACID REAGENT, 441082
- National Stock Number: 6550-00N089639
Product Identification
Product ID:SYNCHRON EL-ISE ACID REAGENT, 441082
MSDS Date:02/10/1992
FSC:6550
NIIN:00N089639
Status Code:A
MSDS Number: CHVKJ
Responsible Party
BREA, CA 92621-6209
US
Emergency Phone: 800-424-9300 (CHEMTREC)
Info Phone: 800-854-3633
Cage: IW937
Contractor
Telephone: 800-854-3633
Cage: IW937
Ingredients
WATER
CAS: 7732-18-5
RTECS: ZC0110000
Fraction By Weight: 99.1%
OSHA PEL N/K
ACGIH TLV: N/K
SULFURIC ACID (SARA 302/313) (CERCLA)
CAS: 7664-93-9
RTECS: WS5600000
Fraction By Weight: 0.9%
OSHA PEL 1 MG/M3
ACGIH TLV: 1 MG/M3/3 STEL
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE (SHORT-TERM): THIS SOLUTION IS
EXTREMELY ACIDIC. MAY CAUSE BURNS OF NOSE, THROAT, SKIN AND EYES.
ADDITIONAL EFFECTS MAY INCLUDE COUGHING, SNEEZING AND NAUSEA.
CHRONIC (LONG-TERM): IN ADDITION TO EFFECTS FROM SHORT-TERM
EXPOSURE, REDNESS AND SWELLING OF SKIN AND EYES MAY OCCUR.
Explanation of Carcinogenicity:SULFURIC ACID: IARC MONOGRAPHS, VOLUME
54, PAGE 41, 1992: GROUP 1. ANIMAL: PULMONARY IRRITATION.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:PERSONS WITH PREEXISTING SKIN AND
EYE CONDITIONS.
First Aid
First Aid:INHAL: REMOVE TO FRESH AIR. IF BREATHING HAS STOPPED, PERFORM
ARTIFICIAL RESP. IF BREATHING IS DIFFICULT, GIVE OXYGEN. GET MED
ATTN IMMED. SKIN: FLUSH W/COPIOUS AMOUNTS OF WATER FOR AT LEAST 15
MINS. REMOVE CONTAM CLOTHING & SHOES. GET MEDATTN IMMED. EYES:
FLUSH W/COPIOUS AMOUNTS OF WATER FOR AT LEAST 15 MINS. ASSURE ADEQ
FLUSHING BY SEPARATING EYELIDS W/FINGERS. GET MED ATTN IMMED. (SUP
DAT)
Fire Fighting
Flash Point:NOT FLAMMABLE.
Extinguishing Media:DRY CHEMICAL OR CARBON DIOXIDE.
Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:PRODS OF COMBUST MAY INCL OXIDES OF
SULFUR. DEPENDING UPON FIRE CNDTNS, COMBUST PRODS MAY BE PRDCED
WHICH RANGE FROM IRRITANTS & ASPHYXIANTS TO ACUTELY(SUP DAT)
Accidental Release
Spill Release Procedures:COLLECT INTO INERT ABSORBENT MATERIAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:STORE AWAY FROM INCOMPATIBLE
SUBSTANCES.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Exposure Controls
Respiratory Protection:IF EXPOSURE LIMIT EXCEEDS TLV, USE NIOSH
APPROVED RESPIRATORS AS APPROPRIATE.
Ventilation:IF EXPOSURE LIMIT EXCEEDS TLV, USE LOCAL EXHAUST.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:EMERGENCY EYEWASH AND DELUGE SHOWER MEETING
ANSI DESIGN CRITERIA . WEAR APPROPRIATE PROTECTIVE CLOTHING.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXPLO HAZ: TOX MATLS WHICH MAY CAUSE DMG TO ORGAN SYS INCL LUNGS,
BLOOD, LIVER, KIDNEYS & CNS. FIRST AID PROC: INGEST: WASH OUT MOUTH
W/WATER. GET MED ATTN IMMED.
Chemical Properties
Boiling Pt:B.P. Text:212F,100C
Spec Gravity:>1
pH:<1
Solubility in Water:100%
Appearance and Odor:COLORLESS LIQUID, ODORLESS.
Stability
Stability Indicator/Materials to Avoid:YES
BASES, ORGANICS, METALS, OXIDIZERS, PICRATES.
Stability Condition to Avoid:STABLE UNDER NORMAL TEMPERATURES AND
PRESSURES.
Hazardous Decomposition Products:THERMAL DECOMPOSITION MAY RELEASE
TOXIC OXIDES OF SULFUR.
Disposal
Waste Disposal Methods:DISPOSE ACCORDING TO LOCAL, STATE AND FEDERAL
REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their